Safety Plus II Technical Data
Technical Data Sheet - Hurricane Impact Resistant Glass
Type:
Special Polymer, specifically blended and designed for laminating safety glass.
Distinguishing Characteristics:
Outstanding clarity & superior strength
Refractive index match to glass
Excellent chemical adhesion to glass
Safety-PlusŪ II mechanical glazing (patent No. 5,778,629)
Cured Properties:
Hardness: Shore A
70
Tensile adhesion to glass
112
Flexural strength
1806 psi
Environmental exposure tests
Passes thermal/humidity cycling
Thermal cycle
4.5C(40F)/74C(165F) 4 cycles; (12 hr/cycle)
Humidity cycle
90.5C(195F)/95%R.H. 48 hrs min.
Testing Data:
South Florida Building Codes
Large missile test
(50'/sec)
Complies
Small missile test
(80'/sec)
Complies
Cyclic wind pressure
(9000 cycles)
Complies
32,000 cycles up to 339 psf @ 0.90
Self ignition
(ASTM D-1929)
Complies
Rate of burning
(ASTM D-635)
Complies
Smoke density
(ASTM DE084)
Complies
Weather test
(6500 watt lamp for 4500 hrs)
Complies
Tensile test
(ASTM D-638)
Complies
Impact
16 CFR 1201 CAT II
Complies
ANSI Z97.1-1984
Complies
Compatibility
Water
1680 hrs
Pass
Mineral spirit
1681 hrs
Pass
Dow 995 Silicone
1682 hrs
Pass
G.E. SCS 2800
1683 hrs
Pass